Model NO.: ESGA-90ISTS
Application Fields: Electroplating
Application Machine: CNC Machine Tools
Certification: CE
Condition: New
Water Chiller Compressor: Taiwan Hanberll
Water Chiller Controller: Punp or Siemens
Water Chiller Expansion Valve: Emerson
Trademark: Eurostars
Specification: CE
Origin: Guangdong, Prc
HS Code: 8418692090
1.Eurostars air cooled screw type water chiller a)Low Noise
b)High Efficient and Energy Saving
c)Easy Operation and Installation
d)Compact Exterior
e)High quality
f)Competitive price
g)CEÂ certificated
Â
2.Eurostars Water Chiller Features
1).The Chiller cooling capacity ranged from 100Kw to 800 Kw.
2). Adopt good quality famous brand HANBELL compressor,high efficiency, low noise, lessÂ
  wearing and long life
3).With high efficiency condener and evaporator
4). World famous brand parts: such Danfoss/ ALCO expansion valve, FUJI contactor other brand like PUNP, Schneider,Siemens;
5). Water chillers have high COP;
6). Stable quality, long using life.Â
7).Heat recovery(optional)can help user produce free hot water, which can be 55C
8). Can be widely used in different area,such as in commercial AC, Massage center, Hospital, Hotel, School, etcÂ
9). Strong unit base frame ensured the equipment stable operationÂ
10). Adopt leading brand PLC or SCM controller
11). Multi-capacity regulation, energy saving, cost cut down greatly for operation and maintenance.
12).Standard model exclude water tank and water pump;but it can be custom-made based on client requirement,such as including chilled water pump,hot water pump and hot water tank;
13).Refrigerant is R407C,R22,but R410A,R134A also available.
14).Power and frequency supply:380~415V-3PH-50HZ;Can customize 220~480V-3PH-60HZ;
15). Chilled water range: 5°C to 20°C
Â
3.Eurostars water chiller main parts photos and brand
4.Eurostars water chiller protection devices
1)Phase reversion protection,Â
2)Phase lack protection,Â
3)Overload current protection,
4)Discharge air temp. protection,Â
5)Low & High pressure protection,Â
6)Low temp. protection,Â
7)Water flow protection.
Â
Â
5.Eurostars water cooled chiller technical parameter
Refrigerant-R22
Air Cooled Chiller Unit (Screw Type Compressor-one compressor) | |||||||||
 Model     ESGA- | 40ISTS | 60ISTS | 80ISTS | 90ISTS | 105ISTS | 115ISTS | 125ISTS | ||
Rated Cooling Capacity | KW | 143 | 204 | 273 | 322 | 373 | 403 | 444 | |
USRT | 40.67Â | 58.02Â | 77.65Â | 91.58Â | 106.09Â | 114.62Â | 126.28Â | ||
XÂ 1000Kcal/h | 122.98Â | 175.44Â | 234.78Â | 276.92Â | 320.78Â | 346.58Â | 381.84Â | ||
 Comp. lnput Power×Qty (KW) | 39.3×1 | 53.7×1 | 71.2×1 | 79.7×1 | 92.3×1 | 100.8×1 | 109.8×1 | ||
Refrigerant | R22 | ||||||||
Power Supply | 3φ-380V-50HZ | ||||||||
Safety Protection | Phase reversion protection, Phase lack protection, Overload current protection, Discharge air temp.  protection, Low & High pressure protection, Low temp.  protection, Reserved water flow protection interface. |
||||||||
Number of Refrigeration Circuit | 1 | ||||||||
Capacity Control (%) | 0, 66, 100 | 0, 50, 75, 100 | |||||||
Refrigerant Charge (Kg) | 30 | 42 | 56 | 68 | 78 | 84 | 93 | ||
Condenser | Ripple Aluminum Fins Around Copper Pipe | ||||||||
Evaporator | Dia.of Pipe (inch) | 2-1/2" | 3" | 3" | 3" | 4" | 4" | 4" | |
Water Side Max Pressure  (MPa) | 1 | ||||||||
Chilled  Water Flow(m3/h) | 24.60 | 35.09 | 46.96 | 55.38 | 64.16 | 69.32 | 76.37 | ||
Water Pressure drop (kPa) | 28 | 33 | 48 | 55 | 61 | 64 | 66 | ||
Axial Fan | Air Flow×1000m3/h | 40.2 | 56.8 | 80.4 | 85.2 | 120.6 | 120.6 | 160.8 | |
Power×Qty (KW) | 2.0×2 | 1.2×4 | 2.0×4 | 1.2×6 | 2.0×6 | 2.0×6 | 2.0×8 |
Air Cooled Chiller Unit with Heat Recovery (Screw Type Compressor-one compressor) | |||||||||
 Model     ESGA- | 40ISVTS | 60ISVTS | 80ISVTS | 90ISVTS | 105ISVTS | 115ISVTS | 125ISVTS | ||
Rated Cooling Capacity | KW | 143 | 204 | 273 | 322 | 373 | 403 | 444 | |
USRT | 40.67Â | 58.02Â | 77.65Â | 91.58Â | 106.09Â | 114.62Â | 126.28Â | ||
XÂ 1000Kcal/h | 122.98Â | 175.44Â | 234.78Â | 276.92Â | 320.78Â | 346.58Â | 381.84Â | ||
 Comp. lnput Power×Qty (KW) | 39.3×1 | 53.7×1 | 71.2×1 | 79.7×1 | 92.3×1 | 100.8×1 | 109.8×1 | ||
Refrigerant | R22 | ||||||||
Power Supply | 3φ-380V-50HZ | ||||||||
Safety Protection | Phase reversion protection, Phase lack protection, Overload current protection, Discharge air temp.  protection, Low & High pressure protection, Low temp.  protection, Reserved water flow protection interface. |
||||||||
Number of Refrigeration Circuit | 1 | ||||||||
Capacity Control (%) | 0, 66, 100 | 0, 50, 75, 100 | |||||||
Refrigerant Charge (Kg) | 30 | 42 | 56 | 68 | 78 | 84 | 93 | ||
Condenser | Ripple Aluminum Fins Around Copper Pipe | ||||||||
Evaporator | Dia.of Pipe (inch) | 2-1/2" | 3" | 3" | 3" | 4" | 4" | 4" | |
Water Side Max Pressure  (MPa) | 1 | ||||||||
Chilled  Water Flow(m3/h) | 24.60 | 35.09 | 46.96 | 55.38 | 64.16 | 69.32 | 76.37 | ||
Water Pressure drop (kPa) | 28 | 33 | 48 | 55 | 61 | 64 | 66 | ||
Axial Fan | Air Flow×1000m3/h | 40.2 | 56.8 | 80.4 | 85.2 | 120.6 | 120.6 | 160.8 | |
Power×Qty (KW) | 2.0×2 | 1.2×4 | 2.0×4 | 1.2×6 | 2.0×6 | 2.0×6 | 2.0×8 | ||
Running Noise dB(A) | 68 | 68 | 68 | 68 | 72 | 72 | 72 | ||
Total Weight (Kg) | 1160 | 1730 | 2590 | 2670 | 2750 | 2930 | 3160 | ||
Running Weight(Kg) | 1270 | 1920 | 2810 | 2900 | 3020 | 3240 | 3450 | ||
Heat Recovery Parameters | |||||||||
Refrigerant Charge (Kg) | 32 | 44 | 59 | 71 | 80 | 87 | 96 | ||
Heat Reclaimed Volume (kw) | KW | 43 | 61 | 82 | 97 | 112 | 121 | 133 | |
USRT | 12.20Â | 17.41Â | 23.29Â | 27.47Â | 31.83Â | 34.39Â | 37.88Â | ||
XÂ 1000Kcal/h | 36.89Â | 52.63Â | 70.43Â | 83.08Â | 96.23Â | 103.97Â | 114.55Â | ||
Heat Recoverer | Dia.of Pipe (inch) | 1-1/2" | 1-1/2" | 1-1/2" | 2" | 2" | 2" | 2" | |
Water Side Max Pressure  (MPa) | 1 | ||||||||
Reclaimed  Water Flow (m3/h) | 7.4 | 10.5 | 14.1 | 16.6 | 19.2 | 20.8 | 22.9 | ||
Water Pressure drop (kPa) | 24 | 23 | 27 | 27 | 26 | 26 | 26 |
Air Cooled  Chiller Unit (Screw Type Compressor-two compressors) | |||||||||
 Model     ESGA- | 140IDTS | 155IDTS | 185IDTS | 195IDTS | 210IDTS | 230IDTS | 255IDTS | ||
Rated Cooling Capacity | KW | 498 | 546 | 644 | 682 | 746 | 806 | 888 | |
USRT | 141.64Â | 155.29Â | 183.16Â | 193.97Â | 212.17Â | 229.24Â | 252.56Â | ||
XÂ 1000Kcal/h | 428.28Â | 469.56Â | 553.84Â | 586.52Â | 641.56Â | 693.16Â | 763.68Â | ||
 Comp. lnput Power×Qty (KW) | 65.4×2 | 71.2×2 | 79.7×2 | 83.4×2 | 92.3×2 | 100.8×2 | 109.8×2 | ||
Refrigerant | R22 | ||||||||
Power Supply | 3φ-380V-50HZ | ||||||||
Safety Protection | Phase reversion protection, Phase lack protection, Overload current protection, Discharge air temp.  protection, Low & High pressure protection, Low temp.  protection, Reserved water flow protection interface. |
||||||||
Number of Refrigeration Circuit | 2 | ||||||||
Capacity Control (%) | 0, 25, 37.5, 50, 62.5, 75, 87.5, 100 | ||||||||
Refrigerant Charge (Kg) | 104 | 112 | 136 | 142 | 156 | 168 | 186 | ||
Condenser |  Ripple Aluminum Fins Around Copper Pipe | ||||||||
Evaporator | Dia.of Pipe (inch) | 5" | 5" | 3"×2 | 3"×2 | 4"×2 | 4"×2 | 4"×2 | |
Water Side Max Pressure  (MPa) | 1 | ||||||||
Chilled  Water Flow(m3/h) | 85.7 | 93.9 | 110.8 | 117.3 | 128.3 | 138.6 | 152.7 | ||
Water Pressure drop (kPa) | 42 | 54 | 44 | 52 | 54 | 55 | 65 | ||
Axial Fan | Air Flow×1000m3/h | 160.8 | 160.8 | 170.4 | 241.2 | 241.2 | 241.2 | 321.6 | |
Power×Qty (KW) | 2.0×8 | 2.0×8 | 1.2×12 | 2.0×12 | 2.0×12 | 2.0×12 | Carbonated Drinks Filling Machine specification: