www.dreamcompressor.com
·        SKF bearing match with high efficiency screw air end.
·        Single stage air compression design, stable air supply.
·        Inlet sound attenuation design, build a low noise working environment to user.
·        1-2 years warranty period for whole machine, 5 years for air end.
Technical Parameters
5.5-30KW:
Model | DM-5AÂ Â | DM-7AÂ Â | DM-11AÂ Â Â Â Â Â Â Â | DM-15AÂ Â Â Â | DM-18AÂ Â Â Â | DM-22AÂ Â Â Â | DM-22AZÂ Â | DM-30AÂ Â Â Â Â | |
Air discharge/Pressure discharge (m3/min,Mpa) Â Â Â Â Â Â Â Â Â |
0.85/0.7 | 1.2/0.7 | 1.7/0.7 | 2.4/0.7 | 3.1/0.7 | 3.8/0.7 | 3.8/0.7 | 5.2/0.7 | |
0.78/0.8 | 1.1/0.8 | 1.6/0.8 | 2.2/0.8 | 2.9/0.8 | 3.5/0.8 | 3.5/0.8 | 5.0/0.8 | ||
0.65/1.0 | 0.95/1.0 | 1.4/1.0 | 2.0/1.0 | 2.7/1.0 | 3.2/1.0 | Â - | 4.3/1.0 | ||
0.5/1.3 | 0.8/1.3 | 1.2/1.3 | 1.7/1.3 | 2.2/1.3 | 2.9/1.3 | Â - | 3.7/1.3 | ||
Electromotor | Power (Kw) |
5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 22 | 30 |
Horsepower (HP) |
7.5 | 10 | 15 | 20 | 25 | 30 | 30 | 40 | |
Noise(dB) | 65±2 | 66±2 | 68±2 | 68±2 | 69±2 | 69±2 | 69±2 | 69±2 | |
Air outlet pipe diameter | G3/4 | G3/4 | G3/4 | G3/4 | G11/4 | G11/4 | G11/4 | G11/4 | |
Unit weight(Kg) | 200 | 240 | 400 | 410 | 590 | 630 | 620 | 680 | |
Dimensions (mm) |
L | 800 | 800 | 850 | 1000 | 1000 | 1050 | 1350 | 1050 |
W | 800 | 800 | 800 | 900Â | 900 | 1050 | 800 | 1150 | |
H | 900 | 900 | 900 | 1150 | 1150 | 1300Â | 1150Â | 1300Â | |
 Cooling air volume (m3/min) |
23 | 23 | 91 | 91 | 100 | 100 | 100 | 100 |
Model Model | DM-37A | DM-37AZ | DM-45A | DM-55A | DM-55AZ | DM-75A | DM-75AZ | DM-90A | DM-90AZ | |
Air discharge/Pressure discharge (m3/min,Mpa) Â Â |
6.4/0.7 | 6.4/0.7 | 8.0/0.7 | 10.5/0.7 | 10.5/0.7 | 13.6/0.7 | 13.6/0.7 | 16.3/0.7 | 16.3/0.7 | |
6.1/0.8 | 6.1/0.8 | 7.7/0.8 | 9.8/0.8 | 9.8/0.8 | 13.3/0.8 | 13.3/0.8 | 16.0/0.8 | 16.0/0.8 | ||
5.7/1.0 | -Â | 7.0/1.0 | 8.7/1.0 | - | 11.6/1.0 | - | 14.6/1.0 | 14.6/1.0 | ||
5.1/1.3 | Â - | 5.8/1.3 | 7.5/1.3 | - | 9.8/1.3 | - | 12.3/1.3 | 12.3/1.3 | ||
Electromotor | Power (Kw) |
37 | 37 | 45 | 55 | 55 | 75 | 75 | 90 | 90 |
Horsepower (HP) |
50 | 50 | 60 | 75 | 75 | 100 | 100 | 125 | 125 | |
Noise(dB) | 70±2 | 70±2 | 72±2 | 73±2 | 73±2 | 75±2 | 75±2 | 75±2 | 75±2 | |
Air outlet pipe diameter | G11/2 | G11/2 | G11/2 | G2 | G2 | G2 | G2 | G2 | G2 | |
Unit weight(Kg) | 840 | 840 | 860 | 1600 | 1700 | 1750 | 1800 | 2000 | 1980 | |
Dimensions (mm) |
L | 1050 | 1600 | 1200 | 1200 | 1800 | 1500 | 1800 | 1800 | 2150 |
W | 1050 | 1000 | 1200 | 1200 | 1200 | 1240 | 1200 | 1400 | 1300 | |
H | 1300 | 1400 | 1500 | 1500 | 1400 | 1600 | 1400 | 1600 | 1550 | |
Cooling air volume(m3/min) | 180 | 180 | 191 | 320 | 320 | 330 | 330 | 400 | 400 | |
Water-cooled cooling | Water volume(T/H) | 2 | 2 | 3 | 5 | 5 | 5 | 7 | 7 | 7 |
Air volume(m3/min) | 23 | 23 | 23 | 23 | 23 | 23 | 23 | 23 | 23 |
Model Model | DM-110A | DM-132A | DM-160A | DM-185A | DM-220A | DM-250A | DM-315A | DM-350A | DM-400A | |
Air discharge/Pressure discharge (m3/min,Mpa) Â Â |
20.8/0.7 | 24.8/0.7 | 28.5/0.7 | 32.5/0.7 | 38.6/0.7 | 43.9/0.7 | 51.2/0.7 | 64.0/0.7 | 74.0/0.7 | |
20.6/0.8 | 24.0/0.8 | 27.0/0.8 | 30.2/0.8 | 36.4/0.8 | 42.5/0.8 | 50.2/0.8 | 62.0/0.8 | 72.0/0.8 | ||
17.0/1.0 | 20.6/1.0 | 23.2/1.0 | 27.0/1.0 | 33.1/1.0 | 38.8/1.0 | 44.5/1.0 | 57.6/1.0 | 62/1.0 | ||
14.2/1.3 | 16.5/1.3 | 19.7/1.3 | 22.5/1.3 | 30.5/1.3 | 34.6/1.3 | 39.5/1.3 | 49.0/1.3 | 56.5/1.3 | ||
Electromotor | Power (Kw) |
110 | 132 | 160 | 185 | 220 | 250 | 315 | 350 | 400 |
Horsepower (HP) |
150 | 180 | 220 | 250 | 300 | 340 | 400 | 480 | 540 | |
Noise(dB) | 75±2 | 75±2 | 75±2 | 78±2 | 78±2 | 78±2 | 80±2 | 82±2 | 83±2 | |
Air outlet pipe diameter | DN65 | DN65 | DN80 | DN80 | DN100 | DN100 | DN125 | DN125 | DN150 | |
Unit weight(Kg) | 3130 | 3330 | 3500 | 3700 | 4800 | 5200 | 7300 | 7900 | 8400 | |
Dimensions (mm) |
L | 2450 | 2450 | 2650 | 2650 | 2800 | 2800 | 4200 | 4200 | 4200 |
W | 1600 | 1600 | 1600 | 1600 | 1950 | 1950 | 2200 | 2200 | 2200 | |
H | 1700 | 1700 | 1800 | 1800 | 2000 | 2000 | 2350 | 2350 | 2350 | |
Cooling air volume(m3/min) | 450 | 450 | 500 | 600 | 900 | 900 | -- | -- | -- | |
Water-cooled cooling | Water volume(T/H) | 10 | 10 | 10 | 12 | 20 | 20 | 25 | 30 | 35 |
Air volume(m3/min) | 100 | 100 | 100 | 100 | 145 | 145 | 200 | 200 | 250 |
Comsumables
No. |
Item |
Replacing Schedule |
1 |
Air Filter Element |
Replace every 1500 hours. |
2 |
Oil Filter Element |
First maintenance (after 500 hours), replace new one. Then replace every 1500 hours. |
3 |
Oil Separator Element |
Replace every 3000 hours. |
4 |
Lubrication oil |
First maintenance (after 500 hours), replace new one. Then replace every 3000 hours. |
Victor
Tel:86-21-67623287
www.dreamcompressor.com
Compact Skip Concrete Mixing Plant
Modular Container-design Mixing Plants with Skip Loading:
Designed for minimum space requirement and large quantities of concrete production performance, durable container modules enable economical transportation,minimum time and operations of erection and disassembling,robust structure reduces the requirement of foundation,leading to economical plant relocations,plant fully enclosed and protected from harsh environment,also low noise and dust emission.
Modular Container-design Mixing Plants with Conveyor Loading:
Quick and easy installation
Cost effective sea and land transportation
Quick and easy relocation
Flexibility in the configuration
Minimum foundation cost
Standard Mixing Plants with Conveyor Loading:
High production capacity
Easy operation and maintenance in wide areas.
High efficiency
Flexibility in configuration
Conformity with special site layouts
Compact Mixing Plants with Skip Loading:
Small space, great performance
Versatile, economical, durable
Compact dimension
Small space, great performance
Versatile, economical, durable
Compact dimension
Compact Skip Concrete Mixing Plant,Wet Mix Concrete Batch Plant,Wet Mobile Mix Concrete Batch Plant,Mini Concrete Batch Plant
Fangyuan Group Co.,Ltd. , https://www.fygcorp.com