Digital Display Vickers Hardness Tester for Metal Glass Ceramics

Model NO.: HVS-50
Calibrating Method: Standard Hardness Test Blocks
Rated Voltage: 220V
Support Language: English
Customized: Customized
Hardness Measurement Range: (5-3000)Hv
Max Height of Specimen: 165mm
Max Width of Specimen: 130mm
Voltage: AC220V/50Hz
Loading Control: Automatic (Load/Hold/Uninstall)
Eyepiece Magnification: 10×
Total Magnification (μm): 100×, 200×
Test Force Retention Time: 1-99s
Test Force: 1-30kgf(9.8n-294n)
Weight: 42kg
Trademark: Biaoke
Transport Package: Wooden Case
Specification: 585*200*630mm
Origin: Wenzhou
HS Code: 9024102000
Digital display vickers hardness tester for metal glass ceramics
 
Digital Display Vickers Hardness Tester for Metal Glass Ceramics

The digital turret-type Vickers hardness tester can meet the basic Vickers hardness test requirements. The upgraded digital micrometer eyepiece can directly read the measurement length, so that the measurement value can be obtained more quickly and accurately. The tower can automatically switch the eyepiece and indenter to avoid artificial errors and damage the instrument, and also greatly improve the efficiency.
Digital Display Vickers Hardness Tester for Metal Glass Ceramics

Applications:
1. Iron and steel, non-ferrous metals, metal foils, hard alloys, metal sheets, microstructures, carbonization;
2. Carburizing, nitriding and decarburization layers, surface hardened layer, plating layer, coating, heat treatment;
3, glass, wafers, ceramic materials.

Technical Parameters:
Vickers hardness scale HV1,HV3,HV5,HV10,HV20,HV30
Display 5-digit hardness value, 4-digit diagonal length (D1, D2),
Hold time, number of tests, average, standard deviation, return
Test force(Kgf) 1.0Kgf(9.8N), 3.0Kgf(29.4N), 5.0Kgf(49.0N), 10Kgf(98.0N), 20Kgf(196N), 30Kgf(294N)
Loading control Automatic (load/hold/uninstall)
Test force retention time(s) 1~99
Optical channel Dual light channels (eyepieces and CCD camera channels)
Optical system Objectives: 10×, 20×
Eyepiece Magnification: 10×
Total magnification (μm): 100×, 200×
Measuring range (μm): 400
Resolution (μm): 0.125
Hardness measurement range (5-3000)HV
XY test stand (optional) Size (mm): 100×100
Travel range (mm): 25×25
Minimum reading (mm): 0.01
Maximum height of specimen (mm) 165
Maximum width of specimen (mm) 130 (distance from the center line of the indenter to the wall)
Data output Reserve built-in mini printer interface, (RS232 serial interface) optional installation
Voltage AC220V/50HZ
Overall size (mm) 585×200×630
Weight (kg) 42

Digital Display Vickers Hardness Tester for Metal Glass Ceramics
       Shanghai Biaoke Photoelectronic Technology Co., Ltd. is a national high-tech enterprise intergrating with R&D, manufacturing and selling. Our company has 12-year experience in laser marking & cutting machine, hardness tester and other instruments. The main products: vickers hardness tester, rockwell hardness tester, leeb hardness tester, shore hardness tester, webster hardness tester, barcol hardness tester, brinell hardness tester, laser marking machine, laser cutting machine, etc. We have the CE, ISO, FDA, SGS Certificates. So our machine used around the golbe in a myriad of markets, such as Germany, Korea, France, Italy, India, Brazil, Arab, Egypt, etc.
Digital Display Vickers Hardness Tester for Metal Glass Ceramics

Digital Display Vickers Hardness Tester for Metal Glass CeramicsStandard configuration
Host computer 1
Weight 3
Large and medium "V" test benches 1
Horizontal adjustment screw 4
Power cable 1
10X digital microscope eyepiece 1
Vickers hardness block 2
Spare fuse 2A 2
Product certificates 1
Instruction manual  

Welcome to contact me!
 
Digital Display Vickers Hardness Tester for Metal Glass Ceramics


 

High Precision Machining

High Precision Machining is defined as a process of changing the dimensions or the performance of workpiece with machining facilities.

According to the temperature of the workpiece while in machining, high precision machining can be divided into cold working and hot working. Usually, machining under indoor temperature, and won't change cause chemical change or phisical phase change is named cold working. On the other hand, if under temperature, higher or lower than room temperature, which will lead to chemical changes or phase changes, it will be called as hot working.

For high precision machining, the machining tolerance can be up to 0.0001-0.001mm, the surface finish Ra can be 0.02-0.1um.

Machining precision is to describe the actual geometrical parameter of the part after machining, such as the size, the form, the position, comparing with the theoretical geometry parameter. The difference from these two parameters is the machining tolerance. The number of the difference show the machining accuracy, the bigger, the lower of the machining precision, the smaller, the higher machining precision.

High Precision Machining,Aluminum Alloy Diecasting,Precision Parts,Machining Parts

NINGBO ZHENHAI BOLANG METAL PRODUCT FACTORY , https://www.aldiecastings.com