The electric constant temperature incubator has many applications in breeding, fermentation and other constant temperature experiments. The microcomputer intelligent temperature controller of the electric constant temperature incubator adopts self-tuning PID technology and has the characteristics of rapid temperature control and high precision. Both the set temperature and the actual temperature are digitally displayed, easy to operate, and have an upper temperature tracking alarm function. The inside of the incubator is made of stainless steel and there are several layers of stainless steel shelves that can be moved and height adjustable. After the outer door is opened, there is a tempered glass door to facilitate observation of the interior of the incubator. The incubator is equipped with a miniature fan to ensure the uniformity of the temperature inside the incubator.
Electric constant temperature incubator use method:
1. Before the power is turned on, check the electrical performance of the incubator first, and pay attention to whether there is an open circuit or leakage.
2, the electric incubator is ready, you can put the sample, close the door, adjust the exhaust valve 3, close the power switch, to the opening, press the button below the instrument. Set the temperature you need, the green indicator light of the instrument is on, and start heating. As the temperature rises, the instrument window displays the measured temperature value. When the set value is reached, the instrument red light turns on and stops heating. When the temperature is lower than the set value, the instrument goes to the green light again, re-heating, and restarting, can keep the temperature near the set value. When using the time ratio, zero-crossing, phase shift adjustment of the instrument, due to the size of the load heating power, resulting in the measured value is higher or lower than the set static error correction, adjust the potentiometer, you can eliminate the deviation to Adapt to different situations.
4. When the temperature is constant, the temperature will continue to rise. This is the effect of residual heat. This phenomenon tends to stabilize after about 90MIN.
5, the goods placed in the box should not be over-crowded, so that the convection of hot and cold air is not blocked, in order to maintain uniform temperature inside the box.
Electric constant temperature incubator use environment:
1. Temperature: 5-----40°C
2. Relative humidity: ≤ 90%
3. Power supply: 220V±22V, frequency: 50HZ±1HZ
4. There is no strong vibration and corrosive gas around.
5. Avoid direct sunlight or other cold and heat sources
Electric constant temperature incubator use method:
1. Before the power is turned on, check the electrical performance of the incubator first, and pay attention to whether there is an open circuit or leakage.
2, the electric incubator is ready, you can put the sample, close the door, adjust the exhaust valve 3, close the power switch, to the opening, press the button below the instrument. Set the temperature you need, the green indicator light of the instrument is on, and start heating. As the temperature rises, the instrument window displays the measured temperature value. When the set value is reached, the instrument red light turns on and stops heating. When the temperature is lower than the set value, the instrument goes to the green light again, re-heating, and restarting, can keep the temperature near the set value. When using the time ratio, zero-crossing, phase shift adjustment of the instrument, due to the size of the load heating power, resulting in the measured value is higher or lower than the set static error correction, adjust the potentiometer, you can eliminate the deviation to Adapt to different situations.
4. When the temperature is constant, the temperature will continue to rise. This is the effect of residual heat. This phenomenon tends to stabilize after about 90MIN.
5, the goods placed in the box should not be over-crowded, so that the convection of hot and cold air is not blocked, in order to maintain uniform temperature inside the box.
Electric constant temperature incubator use environment:
1. Temperature: 5-----40°C
2. Relative humidity: ≤ 90%
3. Power supply: 220V±22V, frequency: 50HZ±1HZ
4. There is no strong vibration and corrosive gas around.
5. Avoid direct sunlight or other cold and heat sources
The Stainless Steel Welding Wire ER308 is Weldability and fluidity are better than 304 Good crack and corrosion resistance due to moderate ferrite content.
general purpose wire for welding AISI321, 347, and equivalent grades, High silicon content for minimal spatter, and weld fluidity.
ER308 is Suitable for welding AISI 304 and 308H steel, good strength at high temperature due to higher carbon content.Er308 S.S Welding Wire,Stainless Tig Wire,Stainless Steel Filler Wire,308 Stainless Steel Mig Wire
Jiangyin Vankey Machinery Technology Co.,Ltd , https://www.jswkweldingwire.com